Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Spine J ; 23(4): 609-620, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36539040

RESUMO

BACKGROUND CONTEXT: Although autologous bone grafting is widely considered as an ideal source for interbody fusion, it still carries a risk of nonunion. The influence of the intervertebral device should not be overlooked. Requirements for artificial spinal devices are to join the vertebrae together and recover the original function of the spine rapidly. Ordered mineralization of apatite crystals on collagen accelerates bone functionalization during the healing process. Particularly, the stable spinal function requires the ingrowth of an ordered collagen and apatite matrix which mimics the intact intervertebral microstructure. This collagen and apatite ordering is imperative for functional bone regeneration, which has not been achieved using classical autologous grafting. PURPOSE: We developed an intervertebral body device to achieve high stability between the host bone and synthesized bone by controlling the ordered collagen and apatite microstructure. STUDY DESIGN: This was an in vivo animal study. METHODS: Intervertebral spacers with a through-pore grooved surface structure, referred to as a honeycomb tree structure, were produced using metal 3D printing. These spacers were implanted into normal sheep at the L2-L3 or L4-L5 disc levels. As a control group, grafting autologous bone was embedded. The mechanical integrity of the spacer/bone interface was evaluated through push-out tests. RESULTS: The spacer with honeycomb tree structure induced anisotropic trabecular bone growth with textured collagen and apatite orientation in the through-pore and groove directions. The push-out load of the spacer was significantly higher than that of the conventional autologous graft spacer. Moreover, the load was significantly correlated with the anisotropic texture of the newly formed bone matrix. CONCLUSIONS: The developed intervertebral spacer guided the regenerated bone matrix orientation of collagen and apatite, resulting in greater strength at the spacer/host bone interface than that obtained using a conventional gold-standard autologous bone graft. CLINICAL SIGNIFICANCE: Our results provide a foundation for designing future spacers for interbody fusion in human.


Assuntos
Transplante Ósseo , Fusão Vertebral , Humanos , Animais , Ovinos , Transplante Ósseo/métodos , Apatitas/química , Coluna Vertebral , Próteses e Implantes , Colágeno/uso terapêutico , Fusão Vertebral/métodos , Vértebras Lombares
2.
Spine J ; 22(10): 1742-1757, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35675865

RESUMO

BACKGROUND CONTEXT: Therapeutic devices for spinal disorders, such as spinal fusion cages, must be able to facilitate the maintenance and rapid recovery of spinal function. Therefore, it would be advantageous that future spinal fusion cages facilitate rapid recovery of spinal function without secondary surgery to harvest autologous bone. PURPOSE: This study investigated a novel spinal cage configuration that achieves in vivo mechanical integrity as a devise/bone complex by inducing bone that mimicked the sound trabecular bone, hierarchically and anisotropically structured trabeculae strengthened with a preferentially oriented extracellular matrix. STUDY DESIGN/SETTINGS: In vivo animal study. METHODS: A cage possessing an anisotropic through-pore with a grooved substrate, that we termed "honeycomb tree structure," was designed for guiding bone matrix orientation; it was manufactured using a laser beam powder bed fusion method through an additive manufacturing processes. The newly designed cages were implanted into sheep vertebral bodies for 8 and 16 weeks. An autologous bone was not installed in the newly designed cage. A pull-out test was performed to evaluate the mechanical integrity of the cage/bone interface. Additionally, the preferential orientation of bone matrix consisting of collagen and apatite was determined. RESULTS: The cage/host bone interface strength assessed by the maximum pull-out load for the novel cage without an autologous bone graft (3360±411 N) was significantly higher than that for the conventional cage using autologous bone (903±188 N) after only 8 weeks post-implantation. CONCLUSIONS: These results highlight the potential of this novel cage to achieve functional fusion between the cage and host bone. Our study provides insight into the design of highly functional spinal devices based on the anisotropic nature of bone. CLINICAL SIGNIFICANCE: The sheep spine is similar to the human spine in its stress condition and trabecular bone architecture and is widely recognized as a useful model for the human spine. The present design may be useful as a new spinal device for humans.


Assuntos
Doenças da Coluna Vertebral , Fusão Vertebral , Animais , Apatitas , Matriz Óssea , Vértebras Cervicais/cirurgia , Colágeno , Humanos , Pós , Ovinos , Fusão Vertebral/métodos
3.
Childs Nerv Syst ; 37(8): 2667-2671, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33108520

RESUMO

Spinal cord subependymomas (SCSEs) in children are extremely rare, and no reports distinguishing SCSEs from syringomyelia have been published. We report a case of a 10-year-old boy who presented with torticollis, scoliosis, as well as pain that had begun in the posterior portion of the neck and progressed to the right shoulder and upper arm. Magnetic resonance imaging showed an intramedullary cyst-like lesion with the same signal intensity as that of cerebrospinal fluid. Idiopathic syringomyelia with scoliosis was first suspected, and a syrinx-subarachnoid space shunt was performed. After surgery, the lesion was slightly smaller; however, 2 years after surgery, it had re-grown, causing excruciating pain but no other symptoms. A second surgery was performed, and gross total resection was achieved. Pathological evaluation revealed SCSE. SCSE needs to be considered as a differential diagnosis for spinal centric cyst-like lesions in children.


Assuntos
Glioma Subependimal , Siringomielia , Criança , Glioma Subependimal/diagnóstico por imagem , Glioma Subependimal/cirurgia , Humanos , Imageamento por Ressonância Magnética , Masculino , Medula Espinal , Espaço Subaracnóideo , Siringomielia/diagnóstico por imagem , Siringomielia/cirurgia
5.
J Prosthodont Res ; 64(4): 417-423, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32061571

RESUMO

PURPOSE: This randomized controlled trial aimed to study the effects of lining mandibular complete dentures with silicone-based resilient denture liners, especially with respect to sensation. METHODS: The trial included completely edentulous patients who were willing to fabricate new set of complete denture. A random permuted block method (block size: 4) was used to assign participants to one of the following groups: mandibular conventional denture (CD) group or mandibular denture with resilient denture liner (RD) group. The outcomes were evaluated using both, objective measures (current perception threshold (CPT) and pain threshold (PT)) for external stimuli measured using the Neurometer CPT® and subjective measures (physical pain and psychological discomfort measured using the Japanese version of Oral Health Impact Profile for Edentulous patients-OHIP-EDENT-J). The outcomes were measured twice, at immediately after completion of denture adjustments (first measurement), and 3 months after the completion of denture adjustments (second measurement). All outcomes were analyzed using the Student t-test. A p-value of <0.05 was considered statistically significant. RESULTS: CPT was significantly higher with RD than CD only at second measurement with frequency level of 2000 Hz and 5 Hz. The pain thresholds were significantly higher in the RD group than the CD group. The physical pain and psychological discomfort scores were significantly lower in the RD group than in the CD group. CONCLUSION: This study concludes that edentulous patients wearing mandibular complete dentures with silicone-based resilient denture liners dull perception mandibular ridge mucosa and felt less pain than those without the liners.


Assuntos
Reembasadores de Dentadura , Resinas Acrílicas , Prótese Total , Prótese Total Inferior , Humanos , Dor , Silicones
6.
J Prosthodont Res ; 63(3): 299-302, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30755360

RESUMO

PURPOSE: This study aimed to investigate whether the mandible is more receptive to external stimuli than the maxilla in patients with complete dentures by comparing regional current perception thresholds (CPTs) and pain threshold (PTs). METHODS: A single operator obtained measurements from maxillae at the incisor foramen and the left side of the greater palatine foramen region and the mandible at the left side of the mental foramen region, using the Neurometer CPT/C device, CPT and PT values from the oral mucosa of 20 edentulous individuals wearing complete dentures were analyzed. Participant characteristics such as mucosal thickness, occlusal force, age, and sex. Mucosal thickness over target regions and occlusal force were measured by the same operator using Krupp SDM and Occlusal Force-Meter GM10s devices. Differences in CPT and PT among the three measurement regions were tested with an analysis of covariance, and post hoc t-tests with the Bonferroni correction. RESULTS: There were no significant differences between the mental foramen, incisor papilla, and greater palatine regions CPT values. PTs obtained at all current frequencies (2000Hz, 250Hz, and 5Hz) were lowest in the mental foramen region and highest in the greater palatine region. Covariates including sex, mucosal thickness, and occlusal force had no significant influence on CPT or PT values at all frequencies. CONCLUSIONS: The mandible exhibits higher receptivity to external pain stimuli than the maxilla.


Assuntos
Mandíbula , Maxila , Prótese Total , Humanos , Limiar da Dor , Palato
7.
J Oral Rehabil ; 46(6): 556-562, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30762250

RESUMO

BACKGROUND: There is little evidence regarding the reliability of CPT and PT measurements to gauge mandibular perception. Thus, this study aimed to evaluate the test-retest reliability of CPT and PT values obtained from the mandibular oral mucosa and to test the bilateral differences in CPT and PT values obtained from the mental foramen region and buccal shelf region by a single operator. METHODS: CPT and PT values were obtained from the mental foramen and buccal shelf regions of 20 volunteers (10 males and 10 females; average age: 26.4 ± 2.6 years) by using the Neurometer CPT/C® device to deliver electrical stimulation. RESULTS: Relative and absolute reliabilities were confirmed over two measurements of CPT and PT over a 7- to 10-day measurement interval. Intra-class correlation coefficients (ICCs) for CPT and PT table obtained from the mental foramen region were >0.8, while most ICC for the buccal shelf region were <0.8. Standard error of measurement, minimal detectable change and Bland-Altman analyses showed that the CPT and PT measurements had no systematic error and could serve as useful methods. At all frequencies, the bilateral difference in CPT and PT values at the mental foramen and buccal shelf region was not significant. CONCLUSION: CPT and PT measurements using a custom-made device that applied an electrical current to the mental foramen region have appropriate reliability to assess intra-oral sensitivity to electrical stimulation in young adults.


Assuntos
Mucosa Bucal , Limiar da Dor , Adulto , Queixo , Estimulação Elétrica , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Adulto Jovem
8.
Acta Med Okayama ; 71(4): 279-289, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28824183

RESUMO

We developed a surface matching-type computed tomography (CT)-based navigation system for total hip arthroplasty (the N-navi; TEIJIN NAKASHIMA MEDICAL, Okayama, Japan). In the registration step, surface matching was performed with digitizing points on the pelvic bone surface after coarse paired matching. In the present study, we made model bones from the CT data of patients whose acetabular shapes had various deformities. We measured the distances and angles after surface matching from the fiducial points and evaluated the ability to correct surface-matching registration on each pelvic form, using several areas and numbers of points. When the surface-matching points were taken on the superior area of the acetabulum, the correction was easy for the external direction, but it was difficult to correct for the anterior and proximal directions. The correction was difficult for external and proximal directions on the posterior area. Each area of surface-matching points has particular directions that are easily corrected and other directions that are difficult to correct. The shape of the pelvis also affected the correction ability. Our present findings suggest that checking the position after coarse paired matching and choosing the surface-matching area and points that are optimal to correct will improve the accuracy of total hip arthroplasty and reduce surgical times.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Prótese de Quadril , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
Acta Med Okayama ; 71(1): 49-57, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28238010

RESUMO

Metals have been used clinically as biomaterials, especially in the orthopaedic and dental fields. Metals used as implants wear at contact surfaces, producing metal particles and metal ions that may be harmful. Newly developed metal implants and methods of implant surface modification are currently under scrutiny. We evaluated the use of electrolytic in-process dressing (ELID) as a surface finishing method for metal implants. Metal implants processed using the ELID method (ELID group) or not processed (Non-ELID group) were inserted surgically into rabbit femurs. The rabbits were sacrificed postoperatively over a 24-week period. We assessed the concentrations of the cytokines, interleukin (IL)-1ß, IL-6, and tumor necrosis factor-α, the resistance to implant pull-out, and histopathology at the implant site. There was no significant difference between the groups regarding the cytokine concentrations or implant pull-out resistance. Many particles indicating wear around the implant were noted in the Non-ELID group (n=10) but not the ELID group (n=13), while a fibrous membrane adhering to the every implant was noted in the ELID group. The formation of a fibrous membrane rather than metal particles in the ELID group may indicate improved biocompatibility, and it suggests that ELID may prevent corrosion in the areas of contact.


Assuntos
Interface Osso-Implante , Materiais Revestidos Biocompatíveis/farmacologia , Procedimentos Ortopédicos/instrumentação , Próteses e Implantes/efeitos adversos , Titânio/farmacologia , Animais , Fêmur/cirurgia , Humanos , Interleucina-6/análise , Fenômenos Mecânicos , Microscopia Confocal , Modelos Animais , Coelhos , Tomografia Computadorizada por Raios X , Fator de Necrose Tumoral alfa/análise
10.
Clin Exp Dent Res ; 3(4): 154-159, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29744194

RESUMO

The irritation and pain associated with oral blood sampling necessary to monitor glycemic control can alter oral sensation, but no studies have measured the reliability of oral sensation testing when performed concurrently with blood sampling. The primary and secondary aims of this study were to verify the measurement reliability of current perception threshold (CPT) and pain threshold (PT) tests performed before and after blood sampling and to investigate the differences in CPTs/PTs obtained from the oral cavity, hand, and foot, respectively. CPT/PT measurements were obtained from the oral mucosa and the tips of fingers and toes of 18 volunteers (10 males and 8 females, average age = 26.3 years) using electrical stimulation at frequencies of 5, 250, and 2,000 Hz. Participants also provided blood samples by pricking their own index fingers with a small needle. All subjects completed the following 3 conditions at once-weekly intervals as follows: (a) sensory measurements followed by blood sampling (SB block); (b) blood sampling followed by sensory measurements (BS block); (c) sensory measurements without blood sampling (CO control block). Cronbach's α coefficients were over 0.78 for the SB, BS, and CO blocks, and are considered to be acceptable for assuring measurement reliability. The oral cavity had significantly lower CPT/PTs than both hands and feet, such that the threshold increased in the order oral cavity < hand < foot. CPT and PT measurements performed concurrently with blood sampling are both reliable and region specific, and for which the oral cavity is the most sensitive testing region.

11.
Clin Exp Dent Res ; 1(2): 80-86, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29744143

RESUMO

The purpose of this study was to determine the characteristics of the pain tolerance threshold (PTT) induced by electrical stimulation of the alveolar ridge. A total of 100 healthy volunteers studying or working at Nihon University School of Dentistry at Matsudo and patients from Nihon University School of Dentistry at Matsudo Affiliated Hospital, including 51 men (58.7 ± 17.6 years old) and 49 women (60.7 ± 17.1 years old), participated in this study. The volunteers were enrolled after obtaining written informed consent. PTT measurements were obtained using a Neurometer CPT/C® device to deliver electrical stimulation around the left greater palatine foramen at frequencies of 5 and 250 Hz. When the stimulus could no longer be tolerated, the participant released a button to automatically discontinue the stimulus. After the distribution of the PTT values was analyzed, the influence of gender, age, and Eichner index on PTT was analyzed. The Eichner index values were divided into three categories: group A (four supporting zones), group B (less than four supporting zones but with anterior tooth contact), and group C (no occlusal contact). The PTT values did not show a normal distribution. There were no significant differences in PTT between men and women. PTT was significantly associated with age (P = 0.017) at 5 Hz in men. There were no significant differences in PTT among the Eichner index groups. The characteristics of the PTT of the alveolar ridge are as follows: (1) age and PTT at 5 Hz are significantly associated with men but not with women, and (2) the Eichner index has no influence on the PTT.

12.
Acta Med Okayama ; 67(6): 351-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24356719

RESUMO

A computer-assisted navigation system to be used for total knee arthroplasties (TKAs) was reported to improve the accuracy of bone resection and result in precise implant placement, but the concomitant surgical invasion and time consumption are clinical problems. We developed a computed tomography (CT)-based navigation system (NNS) to be used for minimally invasive TKA. It requires only the reference points from a small limited area of the medial femoral condyle and proximal tibia through a skin incision to obtain optical images. Here we evaluated the usefulness and accuracy of the NNS in comparison with the commercially available BrainLAB image-free navigation system (BLS). In a clinical experiment, the registration times obtained with the NNS tended to be shorter than those obtained with the BLS, but not significantly so. The NNS group tended to be in the extended position in the sagittal plane of the distal femur within 3 degrees, and the BLS group showed rather flexed deviation in the sagittal plane of the anterior femur.


Assuntos
Artroplastia do Joelho/métodos , Simulação por Computador , Imageamento Tridimensional/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Modelos Anatômicos , Cirurgia Assistida por Computador/métodos , Artroplastia de Substituição/métodos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Prótese do Joelho , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Tomografia Computadorizada por Raios X
13.
J Prosthodont Res ; 57(1): 42-5, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23182927

RESUMO

PURPOSE: The purpose of this study was to investigate whether different types of dentures induced different responses to stimulations in sensory nerve underlying the denture-supporting mucosa using current perception threshold (CPT). MATERIALS AND METHODS: The study population comprised 45 complete denture wearers with a mean age of 69.7 years (CD), 30 partial denture wearers (PD) with a mean age of 67.1 years, and 40 dentulous participants with a mean age of 69.0 years (Dent). Current perception threshold (CPT) on the greater palatine nerve at 2000 Hz, 250 Hz, and 5 Hz, corresponding to A-beta, A-delta, and C fibers respectively, were measured by the Neurometer® NS3000 device. The differences CPTs among CD, PD, and Dent groups were analyzed by Kruskal-Wallis test and Mann-Whitney U test with adjusting the multiple comparisons' inflation of type 1 error rate by a Bonferroni correction. RESULTS: CPTs of CD, PD, and Dent group at 2000 Hz were 61.5±45.8, 53.5±25.3, 33.0±11.4 (10(-2) mA) respectively. CPTs of CD, PD, and Dent group at 250 Hz were 29.2±28.2, 20.1±13.2, 14.3±5.9 (10(-2) mA) respectively. CPTs of CD, PD, and Dent group at 5 Hz were 28.9±23.4, 17.8±12.2, 12.2±5.6 (10(-2) mA) respectively. The CPTs at all frequencies increased in the following order: Dent

Assuntos
Dentaduras , Maxila/inervação , Células Receptoras Sensoriais/fisiologia , Idoso , Humanos , Nervo Maxilar , Mucosa Bucal/inervação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...